500V Electric Meter Calibration Creep Testing Open Circuit Protection

Brand Name : GFUVE

Model Number : GF1021

Place of Origin : BEIJING,CHINA

MOQ : 1SET

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1500SETS/MONTH

Delivery Time : 1-2WEEKS

Packaging Details : CARTON

accuracy : 0.05%, 0.1%

power supply : One Phase AC 85-265V, frequency 50/60Hz.

voltage range : 57.7V, 100V, 220V, 380V; max 500V

current range : 200mA, 1A, 5A, 20A, 100A; max 120A

frequency : 40Hz-70Hz

harmonic : 2-51times

dimension : 325×275×135mm

weight : 8kg

Contact Now

FEATURES

  • Accuracy class 0.05
  • 0-120A, 0-500V
  • Test 3pcs or 2pcs meter synchronously
  • Start testing and creep testing
  • Reference standard and power source integrated
  • Test by automatic or manual
  • 7 inch TFT touch screen
  • Weight light 8Kg
  • Recorder 500 sets energy meter data
  • Overload, short circuit, open circuit protection

TECHNICAL PARAMETERS

Electrical parameters 
Accuracy class 0.05%, 0.1%
Power supply One Phase AC 85-265V, frequency 50/60Hz.
AC Voltage output 
Range 57.7V, 100V, 220V, 380V; max 500V
Adjustment range (0-120)%RG(1)
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability 0.01%/120s
Distortion 0.1% (Non-capacitive load)
Output load max 30VA
Measuring accuracy 0.05%RG
AC Current output 
Range 200mA, 1A, 5A, 20A, 100A; max 120A
Adjustment range (0-120)%RG
Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability <0.01%/120s
Distortion ≤0.1% (Non-capacitive load)
Output load max 50VA
Accuracy 0.05%RG
Power output 
Active power output stability <0.01%RG/120s
Reactive power output stability <0.02%RG/120s
Active power measuring accuracy 0.05%RG
Reactive power measuring accuracy 0.1%RG
Phase Output
Output adjustment range 0°-359.99°
Output adjustment fineness 10, 1, 0.1, 0.01 as optional.
Resolution 0.01°
Accuracy 0.03°
Power factor
Adjusting range -1 ~ 0 ~ 1
Resolution 0.0001
Measurement accuracy 0.0005
Frequency Output
Adjustment range 40Hz-70Hz
Output adjustment fineness 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.
Resolution 0.001Hz
Accuracy 0.005Hz
Voltage /Current/Harmonic Setting
Harmonic number 2-51times
Harmonic content 0-40%
Harmonic phase 0-359.99
Harmonic setting accuracy (10%±0.1%)RD(2)
Power Energy Measurement Error
Active power energy 0.05%RG
Reactive power energy 0.1%RG
Power Pulse Output
Power pulse type active pulse, reactive pulse
Active power pulse output 5V,10mA
Power Pulse Input
Energy pulse type support active and reactive pulse, the highest frequency power
pulse input is 180K.
Mechanical parameters
Dimensions (W×D×H) (mm) 325×275×135
Weight (kg) 8
Environmental conditions
Ambient temperature -10°C to +50°C
Relative humidity 35%-85%

500V Electric Meter Calibration Creep Testing Open Circuit Protection


Product Tags:

500V Electric Meter Calibration

      

Creep Testing Electric Meter Calibration

      

TFT Touch Screen Electric Meter Calibration

      
China 500V Electric Meter Calibration Creep Testing Open Circuit Protection wholesale