Sign In | Join Free | My disqueenfrance.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Electric Meter Calibration >

Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter

  • 1
  • 2

Brand Name : GFUVE

Model Number : GF312D1

Place of Origin : BEIJING,CHINA

MOQ : 1SET

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1500SETS/MONTH

Delivery Time : 1-2WEEKS

Packaging Details : CARTON

accuracy : 0.05%, 0.1%

resolution : 6”TFT (640×480)

power supply : 220V±10%, 50/60Hz

communication port : RS232

test voltage : Phase to Netural 0-480V (Phase to Phase 0-830V)

harmonic : 2nd-64st

test current : 0-12A

frequency : 40-70Hz

dimension : 245×162×60MM

weight : 1.8KG

Contact Now

1.Electrical parameters 
Accuracy class 0.05%, 0.1%
Display 6”TFT (640×480)
Power supply 220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication port RS232
Test voltage
Range Phase to Netural 0-480V (Phase to Phase 0-830V)
Error ±0.05% (30V-480V)
±0.1% (5V-30V)
Voltage measurement temperature drift < 8 x 10 E-6/K
Voltage measurement relative humidity drift < 8 x 10 E-6/RH
Voltage measurement stability < 50 x10 E-6
Voltage measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Test current
Range (direct connection) 0-12A
Error (direct connection) ±0.05% (100mA-12A)
±0.1% (10mA-100mA)
Range (clamp CT) 10mA-120A
Clamp CT Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter Model: Q13
Test range:1mA-120A
Accuracy:0.1%
Ratio:1000:1
Internal diameter:13mm
External diameter:33mm
Lead cable:2.5m
Three phase color label L1=Red,L2=Yellow,L3=Blue
Error (camp CT) ±0.1% (100mA-120A)
Current measurement temperature drift < 8 x 10 E-6/K @ 10mA-120A
Current measurement relative humidity drift < 8 x 10 E-6/RH@ 10mA-120A
Current measurement stability < 50 x10 E-6
Current measurement long term stability < 80 x 10 E-6/Year
Harmonic 2nd-64st
Power & Energy measure error
Active power (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive power (direct connection) ±0.1% (0.1A-12A)
Energy measure error
Active energy (direct connection) ±0.05% (0.1A-12A)
±0.1% (0.01A-0.1A)
Reactive energy (direct connection) ±0.1% (0.1A-12A)
Power/energy measurement temperature drift < 15 x 10 E-6/K
Power/energy measurement relative humidity drift < 12 x 10 E-6/RH@ 10mA-120A
Power/energy measurement stability < 100 x10 E-6
Power/energy measurement long term stability < 160 x 10 E-6/Year
Error display 5 digits with minimum three decimal places XX.XXX%
Phase angle
Range 0°-360°
Resolution 0.01o
Error ±0.05°
Frequency
Range 40-70Hz
Resolution 0.001Hz
Error 0.002Hz
Pulse input
Input channel 2
Input level 5-24V
Input frequency Max. 2MHz
Pulse output
Energy constant 180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio 1:1
Output level 5V
Pulse frequency Standard 400Hz-1KHz, customized max 10KHz
Scanning head
Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter The sampler is equipped with a bracket which can clip/install on the tested electronic and electromechanical meters, and the sampler can insert to the ‘orifice/slot’ in the center of the bracket.
There are 3 status LED indicator:
[AUTO] – scan the turn-plate of the energy meter
[MANU] –Manual input pulse
[LED] – Receive the LED energy pulse
Function Sensitivity can be intelligently adjusted according to ambient light intensity to ensure accuracy measurement.
Function
Vector diagram Yes
Waveform Yes
Energy accumulation Yes
Communication with PC Yes
Overload protection Yes
2.Cable and Accessories
Test Cable Voltage test cable 1SET Cable Length:2m (R,Y,B,Black)
Current test calbe 1SET Cable Length:2m (R,Y,B,Black)
Plug Pin type 1SET (4black,2Red,2Yellow,2Green)
'U' type 1SET (4black,2Red,2Yellow,2Green)
'Ω' type 1SET (4black,2Red,2Yellow,2Green)
Crocodile type 1SET (1Black,1Red,1Yellow,1Green)
Accessories Bag Yes
3.Mechanical parameters
Instrument dimensions (W×H×D) (mm) 245×162×60
Instrument Weight (kg) 1.8
Carry case dimensions (W×H×D) (mm) 450×320×185
Carry case (kg) 10.6
4.Environmental conditions
Ambient temperature -10°C to 55°C
Relative humidity 15%-95%
Environmental protection level IP51
5.Standard
lsolation protection IEC 61010-1:2001
Energy measurement IEC 60736
Reference standard IEC 62052-11
IEC62053-21
IEC62053-22 & IEC62053-23
IEC61010-1:2001
6.Calibration and maintenance
Warranty 5 years
Calibration Lifelong free calibration service
Recommended calibration interval Every two years

Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter


Product Tags:

RS232 Electric Meter Calibration

      

TFT Color LCD Electricity Energy Meter

      

40Hz Electric Meter Calibration

      
China Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter wholesale

Three Phase Electric Meter Calibration TFT Color LCD Electricity Energy Meter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0