Sign In | Join Free | My disqueenfrance.com |
|
Brand Name : GFUVE
Model Number : GF302D
Place of Origin : BEIJING,CHINA
MOQ : 1SET
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1500SETS/MONTH
Delivery Time : 1-2WEEKS
Packaging Details : CARTON
accuracy : 0.05%, 0.1%
power supply : One Phase AC 180-265V, frequency 50/60Hz.
voltage output range : 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional)
current ouput range : 200mA, 1A, 5A, 20A, 100A
each phase output load : 45VA
frequency : 45Hz-65Hz
harmonic : 2-51times
harmonic content : 0-40%
dimension : 500x600x175mm
weight : 28kg
warranty : 3 years
FEATURES
TECHNICAL PARAMETERS
Electrical parameters | |
---|---|
Accuracy | 0.05%, 0.1% |
Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
AC Voltage Output | |
Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.3% (Non-capacitive load) |
Output load | each phase 25VA |
Measuring accuracy | 0.05%RG |
AC Current Output | |
Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.3% (Non-capacitive load) |
Output load | 45VA |
Accuracy | 0.05%RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.05° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0. 0005 |
Frequency Output | |
Adjustment range | 45Hz-65Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V, 10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 500x600x175 |
Weight (kg) | About 27 |
![]() |